![]() ![]() TM 5-6115-465-12
TO 35C2-3-446-1
NAVFAC P-8-625-12
TM 06858B/06859D-12
(b) Electric winterization
Low oil pressure
kit:
20 lb-ft
switch . . . . . . . . . . .
DOD drawing number . . 72-2836
Oil filter . . . . . . . . . 27 ± 2 lb-ft
Operating
. . . . ...
208 to
240
Oil pressure
voltage
volts,
50/60
transmitter . . . . . . 20 lb-ft
or 400
Hz
single
phase
Fuel Injector
mounting screws . .
30-40 lb-ft
Operating
......
14.6 to 12.5
current
amperes
Fuel filter . . . . . . . . 17 ± 2 lb-ft
Operating
Overtemperature
switch . . . . . . . . . . .
12-15 lb-ft
temperature . .
130°F (54.4°C)
to 155°F (67.4°C)
Coolant temperature
transmitter . . . . . . 12-15 lb-ft
(c) Wheel mounting kit:
Optional Equipment.
(14)
DOD drawing number . . . . . . 72-2833
(a)
Fuel burning winteri-
Capacity (maximum) . . . . 3500 lbs.
zation kit:
Towing speed (maximum) . . . 5 MPH
DOD drawing number . .
72-2837
(d) Load bank kit:
Operating
temperature . . . -25°F (-31.7°C)
DOD drawing number . . 72-2866
to -65°F
(-53.9°C)
Load rating
.........
15 KW
Operating voltage . . 24 Vdc
Operating voltage . . . 120/208 or
240/416 Vac
Operating current:
3 phase,
4 wire
.....
17.5 amperes
Starting
(e) Acoustic suppression
....
7.5 amperes
Running
kit:
Fuel consumption . . . . 20 to 23
Model . . . . . . . . . . . MEP-005AAS
cc/min.
Weight increase to
Duty cycle
....
generator set . . . .
Continuous
1426 lbs
Cube of generator set with
kit Installed . . . . . 196.2 cu ft
(15) Fuel System Diagram.
Refer to figure 1-3.
(16) Hydraulic System
Diagram. Refer to figure 1-4.
Change 13
|
|