IDENTIFICATION AND TABULATED DATA. (cont)

TM 5-6115-465-12
TO 35C2-3-446-1
NAVFAC P-8-625-12
T M 06858B/06859D-12
Governor control unit:
(9) Generator (400 Hz Tactical Precise)
Manufacturer . . . . . . . . . . . . . United Technologies
Type . . . . . . . . . . . . . . . . . . . . . . Rotating field syn-
Model No. . . . . . . . . . . . . . . . CU 671C-7
chronous, brushless
DOD drawing number . . . . . . . 81-4903
Load capacity (2000 rpm) . . 30 kw at 400 HZ
Electric actuator:
Current rating (2000 rpm) . 104 amps at 120/208
Vac or 52 amps at
. . . . . . . . . . . . . United Technologies
Manufacturer
240/416 Vac
. . . . . . . . . . . . . . . AGB-130-D4
Model No.
Power factor . . . . . . . . . . . . . . 0.8
DOD drawing number . . . . . . . 81-705
Cooling . . . . . . . . . . . . . . . . . . . Impeller fan
(12) Safety Devices:
Lubrication
requirements . . . . . . . . . . . . None
(a) Low oil pressure switch:
Drive type . . . . . . . . . . . . . . . Direct coupling
Voltage rating . . . . . . . . . . . . 28 Vac
Duty classification . . . . . . . Continuous
Current rating . . . . . . . . . . . . 10 amps
(10) Electro-hydraulic Governing System:
Trip pressure . . . . . . . . . . . . . 17 ± 3 psig
Type system . . . . . . . . . . . . . . . Closed loop feedback
(b) Coolant high temperature switch:
Load measuring unit:
Voltage rating . . . . . . . . . . . . 28 Vdc
Manufacturer . . . . . . . . . . . . . Electromagnetic
Current rating . . . . . . . . . . . . 10 amps
Industries, Inc.
Trip temperature . . . . . . . . . . 220°F ± 3°F (104.8°C
Model No. . . . . . . . . . . . . . . . 69-500
± 1.5°C)
DOD drawing number . . . . . . . 69-785
(c) Speed switch:
Governor control unit:
Type . . . . . . . . . . . . . . . . . . . . . . Centrifugal, manual
Manufacturer . . . . . . . . . . . . . Electromagnetic
Industries, lnC.
Overspeed trip . . . . . . . . . . . . 120 to 122.5 percent
continuous engine
Model No.
speed (2400 to 2450
50/60 HZ  . . . . . . . . . . . . . . . . 69-700
rpm, engine speed is
1200 to 1225 rpm,
DOD drawing number . . . . . . . 69-784
switch speed).
Hydraulic actuator unit:
Element trip and reset . . . . S9-1. Trip - 290-310
Manufacturer . . . . . . . . . . . . . Electromagnetic
Reset - 190-310
Industries, Inc.
rpm
Model No. . . . . . . . . . . . . . . . 69-600-3
S9-2. Trip - 590-610 rpm (50/60 Hz) 825-850 rpm
(400 Hz)
DOD drawing number . . . . . . . 69-790
Reset - 490-510 rpm (50/60 Hz) 725-750 rpm
(400 Hz)
(11) Electric Governing System (MEP 114A):
S9-3.  Trip - 1200-1250 rpm
Type system . . . . . . . . . . . . . . . Closed loop feedback
Reset - Manual
Load measuring unit:
(13) Nut and Bolt Torque Data:
Manufacturer . . . . . . . . . . . . . Electromagnetic
Intake manifold
Industries, Inc.
mounting nuts . . . . . . . . . . . . 35 lb-ft
Model No. . . . . . . . . . . . . . . . 69-500
Exhaust manifold
mounting nuts . . . . . . . . . . . . 35 lb-ft
DOD drawing number . . . . . . . 69-785