IDENTIFICATION AND TABULATED DATA. (cont)
Up
TM-5-6115-465-12 Generator Set Diesel Engine Driven Tactical Skid Mtd. 30 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Next
Figure 1-3. Fuel System Diagram

TM 5-6115-465-12
TO 35C2-3-446-1
NAVFAC P-8-625-12
TO 06858B/06859D-12
c.  The control cubicle of all
(17) AC and DC, 15 and 30
three models have a frequency
KW, 50/60 and 400 Hz, Precise and
adjust rheostat, but it is
Utility, Wiring Diagram, Dwg. No.
functional only on models MEP 104A
72-2205.  Refer to figure FO-1.
and MEP 114A.  Model MEP 005A
accomplishes frequency adjustment
(18) AC Schematic Diagram,
through the manual speed control.
15 and 30 KW, Precise Generator
Sets, Dwg. No. 72-2200 for MEP 104A
d. All three models use the
and 84-805 for 114A. Refer to
same special relay box, but models
figure FO-2.
MEP 104A and MEP 114A are also
equipped with a precise relay box.
(19) DC Schematic Diagram,
The two precise relay boxes are
15 and 30 KW, Precise Generator
identical with the exception that
Sets, Dwg. No. 72-2269 for MEP 104A
the precise relay box of model MEP
and 84-804 for 114A. Refer to
104A contains a frequency selector
figure FO-3.
switch whereas the precise relay
box of model MEP 114A does not.
(20) AC Schematic Diagram,
15 and 30 KW, Utility Generator
e.  Models MEP 104A and MEP 005A
Sets, Dwg. No. 72-2295. Refer to
use the same exciter regulator
figure FO-4.
assembly and cross current
transformer.  These components are
(21) DC Schematic Diagram,
different on model MEP 114A.
15 and 30 KW, Utility Generator
Sets, Dwg. No. 72-2277. Refer to
f. Differences In performance
figure FO-5.
characteristics are given in table
1-1.
(22) Shipping Dimensions and
Weights.  Refer to figure 1-2.
1-7. DIFFERENCES BETWEEN MODELS.
The primary differences between
the models of the generator sets
covered in this manual are as
follows:
a.  Models MEP 005A and MEP 104A
are equipped with a 50/60 Hz
generator.  Model MEP 114A is
equipped with a 400 Hz generator.
b. Model MEP 104A uses an
electro-hydraulic  governor.  Model
MEP 114A uses an electric governor
system.  Model MEP 005A uses a
mechanical governor which is
integral with the fuel injection
pump.
Change 13
1-8.1/(1-8.2 blank)