STARTER LOW VOLTAGE RELAY SOLENOID (SIDE MOUNTED) REPLACEMENT (sheet 1 of 2)
Up
TM-9-2350-222-20-1-4 Combat Engineer Vehicle Full-Tracked M728 2350-00-795-1797 (Hull) Manual
Next
STARTER LOW VOLTAGE RELAY SOLENOID (TOP MOUNTED) REPLACEMENT (Sheet 1 of 2)

TM 9-2350-222-20-1-4
STARTER LOW VOLTAGE RELAY SOLENOID (SIDE MOUNTED) REPLACEMENT
(Sheet 2 of 2)
INSTALLATION:
NOTE
Be sure insulators (E) are placed
b e t w e e n relay solenoid (A) and
e n g i n e mounting bracket (B) as
shown.
Place relay solenoid (A) in position over
1.
mounting bracket (B) with electrical plug
facing front. Using socket and 7/16 inch
wrench, secure solenoid (A) to mounting p
(B) with two capscrews (D), insulators (E),
new self-locking nuts (F).
screw electrical connector (G) to front of
2.
solenoid (A). Tighten, using spanner wrench.
TEST:
Connect powerplant for ground hop (page 5-48).
1.
Start engine (TM 9-2350-222-10). Check to be
2.
sure engine starts smoothly.
Stop engine. Disconnect powerplant from test
3.
set-up (page 5-62).
Install powerplant (page 5-37).
4.
End of Task
Change 5
10-34