TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Next
STARTUP AND OPERATION SUMMARY

TM 5-3740-214-14
SHUTDOWN PROCEDURES (Continued)
Figure 2-37. Insecticide Flowmeter
WARNING
MAKE SURE there are no personnel in front of the nozzle before flushing the fluid lines.
(6) Turn the ignition switch ON and flush the system until the flush tank is emptied.
NOTE
Finished insecticidal spray solutions and flushing rinseate must be disposed of in a manner
consistent with current federal and local regulations.
(7) Shut down the aerosol generator.
(a) Turn the solenoid valve switch OFF.
(b) Turn the ignition switch OFF.
(c) Return the nozzle to the operating position.
(d) Drain any extra soap and water from the formulation tank.
(e) Open the air pressure drain valve.
STARTUP AND OPERATION SUMMARY
The following information outlines the startup and operation instructions in Chapter 2 of this manual.
a.
Preventive Maintenance Checks and Services. Refer to table 2-1 for the preventive maintenance checks
and services.