Figure 2-37. Insecticide Flowmeter
Up
TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Next
Figure 2-39. Temperature Correction Curve

TM 5-3740-214-14
STARTUP AND OPERATION SUMMARY (Continued)
b.
Pre-start Checks.
c.
Engine Startup Procedures.
d.
Operation Checks.
(1) Formulation tank operating pressure should be 10 to 15 psi.
(2) Nozzle operating pressure should be 90 - 100 psi.
(3) If the pressures registering on the gages are outside these limits, turn the aerosol generator OFF and notify your
supervisor.
e.
Calibration Check.
(1) Turn the engine OFF.
Figure 2-38. Aiming of Nozzle
(2) Aim the nozzle into a bucket.
(3) Turn the ignition switch and the solenoid switch ON.
(4) Allow the insecticide to flow for about five minutes.
(5) Record the flowmeter scale reading and the insecticide temperature.
2-34