Click here to make tpub.com your Home Page

Page Title: Table 2-1. Operator Preventive Maintenance Checks and Services
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Section II. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES
Up
TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Next
Table 2-1. Operator Preventive Maintenance Check and Services (Continued)

TM 5-3740-214-14
Table 2-1. Operator Preventive Maintenance Checks and Services
B - Before
D - During
A - After
INTERVAL
FOR READINESS REPORT-
ITEM
ITEM TO BE INSPECTED.
ING, EQUIPMENT IS NOT
NO.
B
D
A
PROCEDURE
READY/AVAILABLE IF:
1
GENERAL
Figure 2-4. Engine Installation
·
·
a. Make sure all component mounting screws, nuts, and
Subassemblies are not
bolts are tightened securely.
tightened securely
b. Make sure all attached engine compressor and
formulation tank parts are securely fastened.
2
ENGINE ASSEMBLY
·
·
Check crankcase oil level.
The oil level is slightly above
or below the low (L) mark
a. Remove plug dipstick (figure 2-5).
on the dipstick
b. Wipe off dipstick and return it to crankcase. Do not
screw it back into crankcase.
c. Remove dipstick again and check oil level. The level
must be kept near the full (F) mark on dipstick.