Table 2-1. Operator Preventive Maintenance Check and Services (Continued)
Up
TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Next
Table 2-1. Operator Preventive Maintenance Check and Services (Continued)

TM 5-3740-214-14
Table 2-1. Operator Preventive Maintenance Check and Services (Continued)
B - Before
D - During
A - After
INTERVAL
FOR READINESS REPORT-
ITEM
ITEM TO BE INSPECTED.
ING, EQUIPMENT IS NOT
NO.
B
D
A
PROCEDURE
READY/AVAILABLE IF:
6
BELTS AND PULLEYS
·
·
Make sure belts do not slip or sag.
The belts are loose or
damaged
Figure 2-9. Pulsation Tank Drain Valve
7
PULSATION TANK
·
a. Open pulsation tank drain valve and drain oil from
There are air leaks around
pulsation tank. Be sure to close valve after oil is drained.
the pulsation tank
b. Make sure there are no air leaks around pulsation
tank manifold or separator pipe.
8
SEPARATOR ASSEMBLY
Figure 2-10. Separator Drain Valve
2-8