Table 2-1. Operator Preventive Maintenance Check and Services (Continued)
Up
TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Next
Table 2-1. Operator Preventive Maintenance Check and Services (Continued)

TM 5-3740-214-14
Table 2-1. Operator Preventative Maintenance Checks and Services (Continued)
B - Before
D - During
A - After
INTERVAL
FOR READINESS REPORT-
ITEM
ITEM TO BE INSPECTED.
ING, EQUIPMENT IS NOT
NO.
B
D
A
PROCEDURE
READY/AVAILABLE IF:
Figure 2-15. Nozzle Air Leaks
WARNING
MAKE SURE solenoid valve switch is turned OFF before
checking nozzle assembly for air leaks.
DO NOT walk in front of nozzle assembly while engine
is operating.
(1) Turn solenoid valve OFF.
(2) Start engine according to engine startup procedures in
Section III.
(3) Check fittings listed below for air leaks:
1. Air cap and knurled ring
2. Fluid nozzle
3. Nozzle body
4. Adjusting nuts and nipples
5. Swivel elbow
6. Pipe joint at pulsation tank