Click here to make tpub.com your Home Page

Page Title: Table 2-1. Operator Preventive Maintenance Check and Services (Continued)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Table 2-1. Operator Preventive Maintenance Check and Services (Continued)
Up
TM-5-3740-214-14 Aerosol Generator Non-Thermal Insecticide Unltra-Low Volume Model XKA (NSN 374001-076-1341) Manual
Next
Table 2-1. Operator Preventive Maintenance Check and Services (Continued)

TM 5-3740-214-14
Table 2-1. Operator Preventative Maintenance Checks and Services (Continued)
B - Before
D - During
A - After
INTERVAL
FOR READINESS REPORT-
ITEM
ITEM TO BE INSPECTED.
ING, EQUIPMENT IS NOT
NO.
B
D
A
PROCEDURE
READY/AVAILABLE IF:
NOZZLE ASSEMBLY (Continued)
(2) Soak the fluid nozzle in acetone (0-A-51 F)to dissolve
the gunk and varnish.
(3) Carefully clean out the fluid nozzle holes with a toothpick
or other soft non-metallic object.
(4) Wipe the fluid nozzle surfaces with a clean rag.
(5) If teflon gasket is stretched out of shape, replace it.
Figure 2-14. Nozzle Assembly
·
c. Reassemble nozzle assembly.
CAUTION
Do not over tighten the fluid nozzle. This would
damage the teflon gasket and cause air leaks.
·
(1) Thread fluid nozzle and teflon gasket into nozzle body.
(2) Install air cap and knurled ring. Tighten knurled ring by
hand.
d. Check nozzle assembly for air leaks.
2-11