![]() ![]() TM 5-3740-214-14
Table 2-1. Operator Preventative Maintenance Checks and Services (Continued)
B - Before
D - During
A - After
INTERVAL
FOR READINESS REPORT-
ITEM
ITEM TO BE INSPECTED.
ING, EQUIPMENT IS NOT
NO.
B
D
A
PROCEDURE
READY/AVAILABLE IF:
NOZZLE ASSEMBLY (Continued)
(2) Soak the fluid nozzle in acetone (0-A-51 F)to dissolve
the gunk and varnish.
(3) Carefully clean out the fluid nozzle holes with a toothpick
or other soft non-metallic object.
(4) Wipe the fluid nozzle surfaces with a clean rag.
(5) If teflon gasket is stretched out of shape, replace it.
Figure 2-14. Nozzle Assembly
·
c. Reassemble nozzle assembly.
CAUTION
Do not over tighten the fluid nozzle. This would
damage the teflon gasket and cause air leaks.
·
(1) Thread fluid nozzle and teflon gasket into nozzle body.
(2) Install air cap and knurled ring. Tighten knurled ring by
hand.
d. Check nozzle assembly for air leaks.
2-11
|
|