Click here to make tpub.com your Home Page

Page Title: Figure 5-4. Lifting Generator Set.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Figure 5-3. Detaching Generator Set from Trailer.
Up
TM-9-6115-652-14-P Power Unit PU-760/M (NSN 6115-00-394-9581) MEP-114A 30 Kw 400 Hz Generator Set Manual
Next
Chapter 6. TEST AND INSPECTION AFTER REPAIR

TM
9-6115-652-14&P
Figure 5-4. Lifting Generator Set.
Installation
b.
When lifting generator set, use lifting equipment with a minimum lifting capacity of 4000
lb.
Do not stand under generator.
Do not permit generator to swing.
Failure to
observe these precautions can cause injury to personnel or damage to equipment.
Attach lifting equipment with a minimum lifting capacity of 4000 lb (1, figure 5-4) to lifting eyes (2) on top
(1)
edges of generator set (3). Insert a rope (4) through each of four tiedown rings (5) on generator set.
With one person at each rope to steady and guide generator set (3), lift generator set and carefully lower
(2)
it onto trailer.
NOTE
Two center mounting screws on each side can be reached through cutouts in trailer frame
under each fender.
Insert eight screws (4, figure 5-3) with beveled washers (5) down through generator set skids into trailer.
(3)
(4)
Working under trailer install one flat washer (6) and one nut (7) on each screw (4).
Position beveled washers (5) so that screw heads are parallel to tops of washers. While holding beveled
(5)
washers in position, tighten hardware.
Connect generator set ground wire (1) to trailer GROUND TERMINAL stud (3).
(6)
5-4