Figure 3-22. Case top assembly, exploded view
Up
TM-3-6665-302-34 Detector Unit Chemical Agent Automatic Alarm M43 and Chemical Agent Automatic Alarm M42 Manual
Next
Knobs, Boots, and Plunger

TM 3-6665-302-34
(3) Unsolder wire from defective contact
(2) Install pump assembly in detector unit
and remove contact.
assembly (para 3-25).
b. Installation.
3-43. Contacts
(1) Solder wire to contact (55 or 75).
(2) Coat solder joint with sealant from
a. Removal.
coating kit (item 6, table 1-1).
(1) Separate detector unit assembly from
(3) Position contact against chassis subas-
bottom case assembly (para 3-7).
sembly (56) and secure with screw (54, 72, or
73).
(2) Remove two screws (72 and 73 or 54)
(4) Attach bottom case assembly to de-
and pull defective contact (74 or 75) away from
tector unit assembly (para 3­8).
chassis subassembly (56).
Section VII. CASE TOP ASSEMBLY (1A2A5)
meter terminals. Remove meter (3) and gasket
3-44. General
(4).
Direct support maintenance personnel are au-
b. Installation.
thorized to repair the M43 detector case top as-
sembly by replacing the horn and horn gasket,
(1) Position gasket (4) on case top assem-
connector cover, meter, and meter gasket, iden-
bly (13).
tification plate, knobs, boots, plunger, binding
(2) Observing polarity, solder wires to
posts, thermostatic switch, connector and con-
meter terminals. Coat soldered joints with seal-
nector gasket, heater assembly, and top assemb-
ant from coating kit (item 6, table 1-1).
ly.
(3) Position meter (3) with meter face as
shown in figure 3­22.
3-45. Connector Cover
(4) Secure meter (3) with screws (1) and
a. Removal.
lockwashers (2).
(1) remove screw (34, fig. 3­17) from case
top assembly (45).
347. Identification Plate
(2) Unscrew cover (20, fig. 3-22).
b. Installation.
a. Removal.
(1) Screw replacement cover (20) onto con-
(1) Remove four screws (30) and lock-
nector (23).
washers (29 ).
(2) Apply sealing compound (item 3, table
CAUTION
l-l) to thread of screw (34, fig. 3-17).
When using penknife or putty knife, do
(3)- Insert screw (34) through chain loops
not damage switch A1S1 (28) located
of plug (32) and chain of cover (20,fig. 3-22).
under identification plate (31).
(4) Replace and tighten screw (34, fig. 3-
(2) Life identification plate (31) from top
17) in case top assembly (45).
assembly (13). If necessary, pry along edges of
identification plate (31 ) to loosen it.
3-46. Meter and Gasket
(3) Stamp identification plate with M43 de-
tector unit lot number and serial number.
a. Removal.
b. Installation
(1) Remove four screws (1) and lock-
(1) Check that switch (28), embedded in
washers (2).
cavity with adhesive, is not below or more than
1/32-inch above surface of top assembly (13).
(2) Lift meter (3) clear of top assembly
(13) and lay meter (3) on side to expose rear
(2) Position identification plate (31) over
terminals.
on case top assembly (13). Lettering must be
(3) Tag and unsolder two wires from
readable when facing receptible (23).