![]() ![]() TM 3-4240-302-30&P-5
LOCATION
ITEM
ACTION
REPAIR
Panel
Wiring
NOTE
Wires 1 through 21, 65 and 66 are 16 AWG.
Wires 22 through 29 are 20 AWG. All other
wires are 22 AWG.
LEGEND
A5
- PRINTED CIRCUIT CARD
GRD
-
GROUND
K1
- FAN RELAY
CB1
- CIRCUIT BREAKER
J2
-
CONNECTOR
R1
- RESIS TOR
CB2
- CIRCUIT BREAKER
J3
-
CONNECTOR
S7
- PRESSURE SWITCH
CB3
- CIRCUIT BREAKER
J4
-
CONNECTOR
T1
- TRANSFORMER
CB4
- CIRCUIT BREAKER
J5
-
CONNECTOR
TB1
- TERMINAL BOARD
CR5
- DIODE
J6
-
CONNECTOR
TP
- TEST POINT
DS1
- INDICATOR
J7
-
CONNECTOR
FL3
- FILTER
JUNC
-
INSULATED JUNCTION