TM 11-6625-3081-23
4-6. CABLE ENTRY PANEL REPAIR (cont)
4-6
INSTALLATION
-
g.
h.
i.
j.
END OF
Prepare surface, ground lead
(31), and hardware (28, 29, 30,
and 32) for application of zinc
chromate primer (para 2-26).
Install ground lead and hardware
(28 thru 32) as shown.
Apply thin coat of zinc chromate
primer over bonded area and hard-
ware (28 thru 32).
Install cable entry panel in
reverse order of removal,
starting with step e.
TASK
4-7. CABLES AND CONNECTORS REPAIR/REPLACEMENT
4-7
Repair or replace cables and connectors using standard maintenance practices.
For electronic station cable wire list data, refer to chapter 3. The cables are
listed in reference designator sequence (1W1, 1W2, etc.).
4-18
|