CABLE ENTRY PANEL 1A14 REPLACEMENT
Up
TM-11-6625-3081-23-4 Electronic Equipment Test Facility TADS/PNVS Augmentation Equipment Manual
Next
CHAPTER  5 DIRECT  SUPPORT  MAINTENANCE  INSTRUCTIONS ELECTRO-OPTICAL  TEST  BENCH  SET

TM  11-6625-3081-23 4-6. CABLE ENTRY PANEL REPAIR (cont) 4-6 INSTALLATION - g. h. i. j. END OF Prepare  surface,  ground  lead (31), and hardware (28, 29, 30, and 32) for application of zinc chromate primer (para 2-26). Install ground lead and hardware (28 thru 32) as shown. Apply thin coat of zinc chromate primer over bonded area and hard- ware (28 thru 32). Install cable entry panel in reverse order of removal, starting with step e. TASK 4-7. CABLES AND CONNECTORS REPAIR/REPLACEMENT 4-7 Repair  or  replace  cables  and  connectors  using  standard  maintenance  practices. For electronic station cable wire list data, refer to chapter 3. The cables are listed in reference designator sequence (1W1, 1W2, etc.). 4-18