Click here to make tpub.com your Home Page

Page Title: Test Equipment and Material
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Chapter 8. GENERAL SUPPORT TESTING PROCEDURES
Up
TM-11-6625-539-14-3 Test Set Transistor TS-1836 C/U Manual
Next
Chapter 9. SHIPMENT AND LIMITED STORAGE AND DEMOLITION TO PREVENT ENEMY USE

TM 11-6625-539-14-3
84. Physical Tests and Inspection
8­2. Test Equipment and Material
a. Test Equipment and Materials. None re-
The only test equipment and material required
quired.
for testing the TS­1836C/U is Voltmeter, Elec-
b. Test Connections and Conditions.
tronic ME­30(*)/U and a 100-ohm, ±1 percent,
(1) No connections are necessary.
1/2-watt resistor.
(2) Remove the test set chassis from its
case.
8-5. Meter OHMS Position Test
a. Test Equipment and Materials. A 100-ohm,
8­3. Modification Work Orders
±1 percent, 1/2-watt resistor is required.
The performance standards listed in the tests
b. Test Connections and Conditions. No con-
(para 8-5 and 8-6)) are based on the assump-
nections are necessary other than those indicated
tion that all modification work orders have been
in c below.
performed. DA Pam 310­7 lists current M WO's.
c. Procedure.
Control settings
step
Performance standard
No.
Test equipment
Test procedure
Meter pointer indicates full
1
None
Polarity switch:
Observe the meter
FWD PNP.
scale on the OHMS scale.
Function switch :
OHMS E-B.
Meter indicates 100 ohms
Same as step 1
Place the 100-ohm resistor
2
--  .
+5%
between the E and B jacks
on the front panel. Observe
the meter.
Same as step 1.
Remove the 100-ohm resistor,
Same as step 1
3
None
and observe the meter.
b. Test Connections and Conditions. Connect
8-6. Test Set F.E.T. Position Test
the equipment as instructed below.
a. Test Equipment and Materials. The only test
equipment required is Voltmeter, Meter ME­30
(*)/u.
c. Procedure.
Control settings
Step
Equipment under test
Test procedure
Performance standard
Teat equipment
No.
ME-30(*)/u
ME­30(* ) /U indicates 100 mv
Polarity switch: FWD
Connect ME-30 ( * ) /U
1
Range selector
PNP.
_5%.
+
switch: 0 . 3
a c r o s s E and B jacks
Function switch:
Observe the indication on the
F. E. T. CAL.
ME­30(*)/U meter.
U.S. GOVERNMENT PRINTING OFFICE: 1977-765-096/459
Change 2