FUNCTION OF CONTROLS AND INDICATORS
Up
TM-11-6625-3059-10 AM/FM Modulation Meter ME-525A/USM (NSN 6625-01-161-1459) Manual
Next
FUNCTION OF CONTROLS AND INDICATORS (cont)

TM 11-6625-3059-10
Item
No.
Control or Indicator
Function
Permit operator to select a display of + peak (FM or
8
PEAK switches
AM), - peak (FM or trough of AM), or PK - PK (peak
average).
2
Lighted annunciator indicates switch selection.
Permit  operator  to  select  desired  full-scale
9
RANGE switches
modulation range (10, 100, or 300 kHz deviation, or
10, 100, or 300% AM).
10
FUNCTION switches
Permit operator to select display function (kHz DEV,
% AM, or LEVEL).  Lighted annunciator indicates
switch selection.
11
LED display
Indicates modulation (kHz DEV or % AM), or if.
level, as determined by FUNCTION switch selection,
by means of 4-digit LED display.
Flashes when digital display is overranged.
12
RANGE annunciator
Permits operator to select automatic or manual if.
13
SET TO 10.00 - AUTO control
level set for AM measurements.
Permits operator to control application of AC power.
14
POWER OFF switch
Provides means for connecting recovered audio
15
AF OUT connector
signal to external equipment.
Provides means for connecting if. signal to external
16
IF OUT connector
equipment.
Provides means for connecting input signal to input
17
RF IN 50-ohm connector
circuits. Input signal must not exceed 7V rms.
This safety requirement symbol directs that it is necessary to refer to the instruction manual.