Page Title: Digital Panel Meter(DPM) Circuits
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Amplitude Modulation (AM) Circuits
Up
TM-11-6625-3059-10 AM/FM Modulation Meter ME-525A/USM (NSN 6625-01-161-1459) Manual
Next
Chapter 2. OPERATING INSTRUCTIONS

TM 11-6625-3059-10
PRINCIPLES OF OPERATION
f.  Digital Panel Meter(DPM) Circuits. The dc signal information supplied by the audio circuits is converted to a
four-digit display by a precision, dual slope integrator. Multiplexed display signals drive the LED display on the front
panel. Proper display decimal point location is determined automatically by logic circuitry. If the LED display circuits
should overrange, an overrange signal is supplied to the logic circuits.
g. Logic Circuits. The logic circuits convert the front panel switch signals to 5-volt, CMOS-compatible control
signals. These signals are supplied to individual circuits of the ME-525A/USM through a three-state instrument control
bus. The logic circuits also generate multiplexed signals which illuminate control and status annunciators on the front
panel.
h. Power Supply Circuits.  The power supply circuits provide regulated, dc voltages.  Six power supplies are
required: + 15-volt, + 10-volt, 15-volt, 5-volt, + 5-volt (A), and + 5-volt (B). Two separate + 5-volt supplies are used to
power the analog and digital sections of the M E-525A/USM to ensure the lowest possible residual modulation.