TB 9-6625-2197-50
(13) If RF power output level of the radar test set (at the just solid waveform point)
including insertion loss of circulator and cable, is not between 2 to 4 dBm greater than (8)
above, perform b (3) and (4) below.
(14) Remove oscilloscope test probe from TJ 29 of control box and connect to TP3 (fig.
13) of the
receiver card.
Figure. 13. Receiver card layout.
(14) Adjust radar test set RF output power to -11 dBm (include circulator and cable
loss).
(15) If oscilloscope does not display waveform (fig. 6, inset J), adjust radar test set RF
power output level until waveform is just solid.
(16) If RF power output level of the radar test set (at the just solid waveform point),
including insertion loss of circulator and cable, is not between -9 and -13 dBm, perform b
(5) and (6) below.
25