Custom Search
 
  
 
TM 9-2815-220-24
FUEL INJECTION PUMP LINKAGE REPLACE/REPAIR
0124 00
ASSEMBLY
WARNING
Retaining rings are spring tension devices, take care when removing
or installing them. They can slip or break and become airborne
causing eye damage or other bodily harm.
1. Install two new retaining rings (36) (item 12, WP1075) and two new ball bearings (35) (item
322, WP 0175) into rotating eye bracket (26).
2. Install straight shaft (28) into rotating eye bracket (26).
3. Install two bearing shields (34) and two new retaining rings (33) (item 21, WP 0175) on
straight shaft (28).
4. Install new woodruff key (32) (item 103, WP 0175) in straight shaft (28).
5. Install bell crank (15) onto straight shaft (28).
a. Secure using screw (30) and new lock washer (31) (item 93, WP 0175).
6. Attach new spring (29) (item 258, WP 0175) to angle bracket (25) and to rotating eye
bracket (26).
25
15
29
33
34
35
32
36
26
36
35
34 33
31
28
30
WP 0124 00-6

 