LO 5-3895-373-12
Note 15
SEMI ANNUAL or 750 HOURS
AUGER/CONVEYOR DRIVE CHAINS
A
Remove hex head cap screws (1), flat washers
(2), square flat washers (3), and cover plate (4).
B
Lubricate chain assemblies (5) with GAA using a
brush.
C
Run the auger/conveyor system per TM 5-3895-
373-10 to move the unlubricated chains to the
open cover plate area. Lubricate chain. Repeat
this process until both chains have been
completely lubricated.
WARNING
Thread locking compound solvent
can cause eye damage. Wear safety
contact with eyes.
If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
D
Clean threads of hex head cap screws (1) with
thread locking compound solvent. Wipe dry with
a clean cleaning cloth.
E
Assemble flat washers (2) onto hex head cap
screws (1). Install square flat washers (3) onto
two of the cap screws.
WARNING
Thread locking compound can cause
eye
damage.
Wear
safety
contact with eyes.
If compound
contacts eyes, flush eyes with water
G
Install cover plate (4) and secure with hex head
and get immediate medical attention.
cap screws (1).
F
Apply thread locking compound to threads of
H
Tighten hex head cap screws (1) to 37 Ib-ft (50
hex head cap screws (1).
Nm).
Card 15 of 28