NOTES - CONTINUED:
6. ENGINE OIL FILTER. Filter is to be replaced each
time an engine oil change is directed by AOAP
laboratory.
After installing new filter element, fill
crankcase, operate engine 5 minutes, check housing for
leaks, check crankcase oil level and bring to full mark.
When AOAP laboratory support is not available, install
new filter element each 100 hours.
7. BRAKE ACTUATOR. Each 250 hours lubricate 2
fittings on brake actuator with GAA.
8. WHEEL BEARINGS. Each 1000 hours, remove
wheels, clean and inspect all parts, replace damaged or
worn parts, repack bearing and assemble. Rotate
stationary wheel bearings several turns weekly.
9. HYDRAULIC OIL FILTER. Each 1000 hours,
remove filter element, clean housing, install new
element. After replacement, operate hydraulic system
for 5 minutes, check for leaks, check level and bring to
"FULL" mark.
10. UPPER GEAR BOX/LOWER GEAR BOX. Check
level each 50 hours. Change gear lubricant only when
water, or other foreign material. After refill, operate for
five minutes, check for leaks and bring oil level to level
plug opening.
11. TORQUE ARM REDUCERIPUGMILL GEAR CASE.
Check level each 10 hours. Change gear lubricant only
when required by maintenance repair action,
refill, operate for 5 minutes, check for leaks and bring oil
Copy of this Lubrication Order will remain with the
to "FULL" mark.
equipment at all times, instructions contained herein are
mandatory.
12. LUBRICANTS. The following is a list of lubricants
with military symbols and applicable specification
By order of the Secretary of the Army:
numbers.
JOHN A. WICKHAM, JR.
OEIHDO
MIL-L-2104
General, United States Army
GO
MIL-L-2105
Chief of Staff
GAA
MIL-G-10924
OFFICIAL:
OEA
MIL-L-46167
ROBERT M. JOYCE
(SD), Type II
P-D-680
Major General, United States Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with DA Form 12-25B,
Operator and Organizational maintenance requirements
for Mixer.
TA 220197
LO 5-3895-287-12
CARD 7 OF 7
* US. GOVERNMENT PRINTING OFFICE: 1984-420-903/206