LO 5-3895-221-12
NOTES - CONTINUED:
6. ENGINE. Oil is to be changed each 100 hours.
8. AIR CLEANER. Each 10 hours, refill reservoir to
Drain when lubricant is warm.
level mark. Each 50 hours disassemble entire unit,
clean, re-oil and assemble.
7. ENGINE OIL FILTER. Each 100 hours, remove filter
9. LUBRICANTS. The following is a list of lubricants
element, clean housing and install new filter element.
with military symbols and applicable specification
After installing new filter element, fill crankcase, operate
numbers.
engine for 5 minutes, check housing for leaks, check
crankcase oil level and bring to "FULL" mark.
OE/HDO
MIL-L-2104
GAA
MIL-G-10924
OEA
MIL-L-46167
CW
VV-L-751
(SD), Type II
P-D-680
Copy of this Lubrication Order will remain with the
equipment at all times, instructions contained herein are
mandatory.
By order of the Secretary of the Army:
JOHN A. WICKHAM, JR.
General, United States Army
Chief of Staff
OFFICIAL:
ROBERT M. JOYCE
Major General, United States Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with DA Form 12-25B,
Operator and Organizational maintenance requirements
for Concrete Mixers.
TA 220412
U.S. GOVERNMENT PRINTING OFFICE: 1984-420-903/204
CARD 6 OF 6