TM 5-3825-229-14&P
4-20. 12- AND 24-VOLT RECEPTACLES (cont)
a. Test. For testing procedures, refer to para. 4-21.
b. Removal.
(1)
12-Volt Receptacle.
(a)
Remove six screws (4) and washers (5) from nose box cover (6).
(b)
Gently pull nose box cover (6) away from nose box.
(c)
Tag wires (18) on 12-volt receptacle (12).
(d)
Remove seven screws (17) from receptacle (12).
(e)
Remove wires (18) from receptacle.
(f)
Remove nut (8), washer (7) and screw (2) holding receptacle to nose box cover.
(g)
Remove receptacle (12) and gasket (3) from cover.
(h)
Remove circuit breaker (13) from receptacle.
(2)
24-Volt Receptacle.
(a)
Disconnect wires from 24-volt receptacle (1).
(b)
Remove four nuts (I 1) washers (5) and screws (1 5) and remove cover (1 4) and
receptacle (1) from cover.
(3)
Converter.
(a)
Disconnect harness wires from converter (1 0).
(b)
Remove screws (1 6) and remove converter (1 0) from nose box.
c. Installation.
(1) Converter.
(a)
Install converter (1 0) in position in nose box.
(b) Secure converter inside nose box with screws (1 6).
(2) 24-Volt Receptacle.
(a)
Install 24-volt receptacle (1) and cover (14) on cover (6) and secure to cover with screws
(15).
(b)
Connect harness wires and converter wires to receptacle.
4-40