TM9-2320-363-20-1
Section 4
TROUBLESHOOTING CHARTS
D. CHART 2 - ENGINE CRANKS BUT WILL NOT START (Contd.)
STEP/SEQUENCE
C2-15 Check if Injector Drive
or Return Lines are
Shorted to Ground
l Disconnect the 6-way power
harness connector at the ECM.
l Read resistance between socket
C of the 6-way, power harness
connector to the following sockets
on the injector harness connectors
A, B, C, D, E, G, H, J, K, and L.
C2-17 Check DDEC Fuses
l Check both ECM power fuses
RESULT
I
WHAT TO 00 NEXT
Contact Direct Support.
A short to ground on wire
where resistance was less than
10,000 ohms. Contact Direct
Support. Then go to C2-30.
G o t o C 2 - 2 8 .
G o t o C 2 - 1 8 .
3-149