Back
AIR  CONDITIONER
Up
/.25ton/TM-9-2320-289-34 CUCV Series Trucks at intermediate direct support and general support level Manual
Next
AXLES

TM   9-2320-289-34 Table   2-1.   Mechanical   Troubleshooting   (Con’t) MALFUNCTION TEST   OR   INSPECTION CORRECTIVE    ACTION Step  7. Feel  evaporator  outlet  line  for  warmth.  If  evaporator  outlet  line  is  warm,  check  for frost  spots  on  line.  Frost  spots  on  line  indicate  restrictions. If   evaporator   outlet   line   is   restricted,   clear   restrictions. If  evaporator  outlet  line  is  not  restricted,  perform  step  8. Step  8. Check  expansion  valve  temperature  sensing  bulb  positioning.  It  should  be  wrapped securely   to   evaporator   outlet   line   with   thermal   insulation   tape.   (Item   67, Appendix  B)  Thermal  insulation  tape  should  completely  cover  temperature  sensing bulb. Adjust   positioning   if   not   correct. If   positioning   is   correct,   perform   step   9. Compressed   air (207   kPa).   Use WARNING used  to  test  expansion  valve  should  never  exceed  30  psi only   effective   chip   guarding   and   Personnel   protective equipment   (goggles/shield,   gloves.   etc.).   Failure   to   follow   this   warning may   result   in   serious   injury   to   personnel. Step  9. Remove   expansion   valve.   (See   paragraph   10-27)   Check   expansion   valve   for clogged   inlet   screen. Clear  inlet  screen  if  clogged. If  inlet  screen  is  not  clogged,  attempt  to  blow  through  expansion  valve  using compressed  air  not  to  exceed  30  psi  (207  kPa).  If  unable  to  blow  through expansion  valve,  replace  expansion  valve. 2. LOW  OR  NO  AIR  FLOW Step  1. Remove   condenser   cover   assembly, buildup   on   evaporator   coils.   If   there   is (See  paragraph  10-20) If  low  pressure  gage step  2. If  low  pressure  gage receiver-dehydrator. (See   TM   9-2320-289-20)   Check   for   ice ice   buildup,   test   air   conditioning   system. indicates  that  low  side  is  below  specifications,  perform indicates  that  low  side  is  within  specifications,  replace (See  paragraph  10-27) 2-11

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing