Table  2-5.  Organizational  Troubleshooting  (cont).
Up
TM-5-3610-286-20 Topographic Suppoprt System Press Section Printing Press Model SOR NSN 3610-01-214-1245 Manual
Next
Table  2-5.  Organizational  Troubleshooting  (cont)



TM 5-3610-286-20 Table  2-5.  Organizational  Troubleshooting  (cont). Malfunction Test  or  inspection Corrective  action 4.  FEEDER  BOARD  DOES  NOT  RAISE  INTO  POSITION. WARNING HIGH   VOLTAGE •     Do not operate printing press until you are sure TSS Press Section is connected to a suitable ground. Failure to do so may result in death or serious  injury. •     Shut off power source before attempting to disconnect, service, or con- nect wires or cables. Failure to do so may result in death or serious injury. •    When working on high-voltage components, always have an additional person present, and keep one hand away from equipment to reduce hazard of current flowing through vital organs of body. Remove all jewelry from fingers,  wrists,  and  neck  prior  to  working  on  electrical  components. Failure to do so may result in death or serious burns. Step 1. Visually  check  for  mechanical  binding  of  chains,  sprockets,  or  guides  of  pile  lift mechanism. Adjust, repair, or replace components (para.  2-90). Step 2. Turn panel breakers and main power switch ON. Check that feeder motor circuit breaker is ON. Press contactor (c5a) button in. If motor does not operate, go to step 3. If motor operates, go to step 4. NOTE Main pile up pushbutton must be pressed to perform this step. Step 3. Using a multimeter set to range higher than 24V dc, check for 24V dc at point 161 and negative ( - ) on terminal strip. If power is present, go to step 4. If power is not present, replace main pile feeder brake (s7), (figure FO-1  and  para.  2-90). 2-26