Table  2-5.  Organizational  Troubleshooting  (cont).
Up
TM-5-3610-286-20 Topographic Suppoprt System Press Section Printing Press Model SOR NSN 3610-01-214-1245 Manual
Next
Table  2-5.  Organizational  Troubleshooting  (cont).



TM 5-3610-286-20 Table  2-5.  Organizational  Troubleshooting  (cont). Malfunction Test  or  inspection Corrective  action 3.  MAIN  POWER  CONTROL  LIGHT  LIGHTS,  BUT  MAIN  DRIVE  MOTOR  (ml)  DOES  NOT  OPERATE  WHEN OPERATION PUSH BUTTON (b14) IS PRESSED (cont). Step 1. Step 2. Step 3. Step 4. Step 5. Set  SAFETY  STOP  PUSHBUTTONS  and  MACHINE  SAFE  PUSHBUTTONS  to  proper operating  positions.  Ensure  that  cylinder  guard  switch  (b135),  defIector  safety limit switch (b30), ink unit safety guard switch (b26), form roller limit switch (b31), and plexiguard limit switch (b42) are in operate position to allow press to run. Using a multimeter set to range higher than 120V ac, check for 120V ac between input  side  of  fuses  (e3)  and  ground  (refer  to  figure  FO-1). If power is present, go to step 4. if no power is present, go to step 3. Turn main power switch OFF. Using a multimeter set to ohms scale, check continuity of wire between main power switch and fuses (e3). If continuity is present, check that main panel breakers are ON. If  no  continuity,  replace  wiring. Using a multimeter set to range higher than 120V ac, check for 120V ac between output side of fuses (e3) and ground (figure FO-1). If power is present, go to step 5. If no power is present replace fuses (e3) (para. 2-93). Using a multimeter set to range higher than 120V ac, check for 120V ac between point L1 of input side of contactor (c2) and ground, and repeat for points L2 and L3. If power is present, go to step 6. If no power is present, replace wiring (figure FO-1). 2-24