Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Table 2-5. Organizational Troubleshooting (cont).
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
Table  2-5.  Organizational  Troubleshoot/rig  (cont).
Up
TM-5-3610-286-20 Topographic Suppoprt System Press Section Printing Press Model SOR NSN 3610-01-214-1245 Manual
Next
Table  2-5.  Organizational  Troubleshooting  (cont).



TM  5-3610-286-20 Table  2-5.  Organizational  Troubleshooting  (cont). Malfunction Test  or  inspection Corrective  action 2. SHEET  COUNTER  IS  ON  AND  DOES  NOT  OPERATE  (cont). 3. Step 5. Step 6. Step 7. Using a multimeter set to ohms scale, check fuse (e5) for continuity. If continuity is present, go to step 6. If  no  continuity  is  present,  replace  fuse  (e5)  (para.  2-93). Using a multimeter set to range higher than 24V dc, check for 24V dc on output side  of  rectifier. If no power is present, replace rectifier (para. 2-93). If power is present, replace limit switch (b141) (figure FO-1). With one person depressing relay button relay (d14) and other person using a multimeter set to range higher than 24V dc, check for 24V dc at sheet counter on/off switch. If  no  power  is  present,  replace  sheet  counter  (para.  2-94). If  power  is  present,  replace  switch  (para.  2-94). MAIN  POWER  CONTROL  LIGHT  LIGHTS,  BUT  MAIN  DRIVE  MOTOR  (ml)  DOES  NOT  OPERATE  WHEN OPERATION Pushbutton (b14) IS PRESSED. WARNING HIGH VOLTAGE l Do not operate printing press until you are sure TSS Press Section is connected to a suitable ground. Failure to do so may result in death or serious injury. l Shut off power source before attempting to disconnect, service, or con- nect wires or cables. Failure to do so may result in death or serious injury. l When working on high-voltage components, always have an additional person present, and keep one hand away from equipment to reduce hazard of current flowing through vital organs of body. Remove all jewelry from fingers,  wrists,  and  neck  prior  to  working  on  electrical  components. Failure to do so may result in death or serious burns. 2-23

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing