Page Title: Table 2-5. Organizational Troubleshooting
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
SYMPTOM  INDEX
Up
TM-5-3610-286-20 Topographic Suppoprt System Press Section Printing Press Model SOR NSN 3610-01-214-1245 Manual
Next
Table  2-5.  Organizational  Troubleshooting  (cont)



TM 5-3610-286-20 Table  2-5.  Organizational  Troubleshooting. Malfunction Test  or  Inspection Corrective  action 1. MAIN POWER CONTROL LIGHT WILL NOT LIGHT WHEN MAIN POWER SWITCH IS TURNED ON. WARNING l l l HIGH VOLTAGE Do not operate printing press until you are sure TSS Press Section is connected to a suitable ground. Failure to do so may result in death or serious  injury. Shut off power source before attempting to disconnect, service, or con- nect wires or cables. Failure to do so may result in death or serious injury. When working on high-voltage components, always have an additional person present, and keep one hand away from equipment to reduce hazard of current flowing through vital organs of body. Remove all jewelry from fingers,  wrists,  and  neck  prior  to  working  on  electrical  components. Failure to do so may result in death or serious burns. Step 1. Step 2. Step 3. Assure that Press Section panel circuit breakers are ON. Using a multimeter set to range higher than 220V ac, check for 220V ac at output side of press section load center circuit breakers. If no power is present, refer to press section electrical troubleshooting in  TM  5-3610-287-24. If power is present proceed to step 2. Using a multimeter set to range higher than 220V ac, check for 220V ac at input terminals  to  main  power  switch. If power is present, proceed to step 3. If no power is present, check wiring to press and replace as required. Using a multimeter set to a range higher than 220V ac, check for 220V ac at main power  switch  output  terminals. If power is present, proceed to step 4. If no power is present, replace main power switch (para. 2-93). 2-20