Figure 4-9. Multipurpose shelter leveling (sheet 2 of 2 )
Up
TM-10-5410-223-14-1 Shelter Multi Purpose Medical Unit Self-Contained Transportable (MUST); (Brunswick Model CW1) NSN 5410-00-809-6634 Manual
Next
Figure 4-11. Air lock adapter, removal (sheet 1 of 3 )

TM 10-5410-223-14/1
Table 4-2. Troubleshooting (Cont'd)
Malfunction
Test or Inspection
Corrective Action
3. FOLDING FLOOR PANEL NOT LEVEL
Check folding floor support cable assembly.
Refer to figure 4-10 and adjust accordingly.
a. Remove clips from body.
b. Turn body to tighten the wire rope.
c. Install clips.
Figure 4-10. Folding floor support cable, adjustment.
Section VI. MAINTENANCE OF AIR LOCK ADAPTER ASSEMBLY, AIR LOCK
ASSEMBLY AND FABRIC ENCLOSURE
a. Removal. Refer to figure 4-11 and remove the
4-15. Air Lock Adapter Assembly
air lock adapter from the shelter.
NOTE
The below listed removal instructions cover removing
an adapter already in the erected position.