TB 9-4940-302-30
support angles, into storage cabinet
Installation--Continued
5.
tops, two holes per storage cabinet
top. Reposition two support angles and
Fabricate two support angles
secure to wall-mounted blind rivet nuts
(11021151-4) in accordance with figure
6.
45) and four 5/16- x 3/4-in. hex head
capscrews (MS90725-32). Secure support
Fabricate eight adapter plates
angles to storage cabinet tops using
(11021189) in accordance with figure
four 5/16-in. lockwashers (MS35338-45)
16. Using the welding instructions in
and four 5/16- x 1-in. hex head lag
bolts (MS16992-520).
weld one adapter plate to each 2-inch
square tubing table leg of the 14-in.
bed and 30-in. bed industrial sewing
CAUTION
Remove storage cabinet
machines.
drawers adjacent to hole
Secure four casters (11021187)
(two on front end of each industrial
(3) Drill two 0.19-in. diameter
sewing machine) and four rigid casters
holes in metal side of storage cabinet
(11021188) (two on rear end of each
industrial sewing machine (see fig.
strap loop (MS51939-3) to storage
18)), using thirty-two 3/8- x 1-in. hex
cabinet using two 3/16-in. blind rivets
head capscrews (MS90725-60), thirty-two
(MS20601-MP6W2).
thirty-two 3/8-in. hex nuts (MS51967-
(4) Position and secure portable
cabinet and floor-mounted eyebolt using
Follow steps (1) thru (11) below
for equipment installation in the ISO-
a 30-in. retaining strap (7550588-8) in
2-1 shelter, unit 2.
(5) Using a strap loop (MS51939-
(1) Position two storage cabinets
3) as a template, mark and drill four
0.09-in. diameter pilot holes in storage
and 11. Mark and drill three 0.34-in.
diameter holes through storage cabinet
and secure two strap loops to storage
bottoms (two holes in storage cabinet
cabinet top using four #10 x 1-in. flat
closest to front end). Locate holes at
head wood screws (MS35492-78). Secure
the edges allowing for minimum required
portable electric belt sander (5130-00-
clearance for 5/16-in. hex head capscrews.
596-9725) to storage cabinet using a
Secure storage cabinets to floor using
30-in. retaining strap (7550588-8) in
45), two 5/16- x 1-in. hex head capscrews
(MS90725-34) used with the two 5/16-in.
(6) Position 14-in. bed indus-
floor-mounted blind rivet nuts, and one
5/16- x 3/4-in. hex head capscrew
in front left corner in accordance with
(MS90725-32) in accordance with figure
10.
36-in. retaining straps (7550588-4),
passed through floor-mounted eyebolts
(2) Position two support angles
and wrapped around table legs, in
(11021151-4) against right side wall
and on top of the two storage cabinets
(7) Secure electrical power cable
support angles as templates, mark and
drill four 0.19-in. diameter pilot
shelf of 14-in. bed industrial sewing
holes, 2-1/2-in. from each end of the
10