TM 55-4920-438-13&P
3-14. Fixtures - Water Feed Thru Connector - Replace
3-14
This task covers: Replacement of connector
INITIAL SETUP
Tools:
Tool Kit, Power Train, NSN 5180-00-003-5267
Materiel:
New feed thru connector - App E
Adhesive, Sealant NSN 8040-00-877-9872
Personnel Required:
68D Aircraft Power Train Repairer and Helper
REPLACEMENT
1. Have helper hold nut (1) inside shelter.
2. Remove six screws (2), securing connector (3) in place.
3. Remove connector (3) from wall and scrape off old sealant
(4).
4. Details for fabrication of new connector are in App E.
GO TO NEXT PAGE