Click here to make tpub.com your Home Page

Page Title: Table 4-2. SPEED Meter Verification
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Verification - continued
Up
TM-55-4920-431-13 Auxiliary Power Unit Electronic Sequence Unit Multi-Purpose Test Set NSN 4920-01-121-0605 Manual
Next
Chapter 5. PARTS LIST

TM 55-4920-431-13
Reconnect negative terminal wire to negative terminal of TEMP meter.
an.
Replace front panel assembly in case.
ao.
ap.
Disconnect test equipment.
SPEED Meter Verification
TACH  METER
CURRENT
INPUT
FREQUENCY
% RPM
HIGH
LOW
LOW
HIGH
1027
840
20
32
34
1960
1773
65
40
68
2893
2706
60
98
102
3826
130
136
3640
80
4759
170
163
4573
100
5693
5506
204
196
120
TEMP Meter Verification
INPUT
FREQUENCY
TEMP
METER
CURRENT
F
HIGH
LOW
HIGH
LOW
443
35
44
300
405
75
610
600
84
571
775
115
124
900
737
155
942
164
1200
904
1110
195
204
1500
1068
PREPARATION FOR STORAGE OR SHIPMENT
Section V.
4-31.  Packing for Shipment or Storage.  The original shipping container should
be used for packing the tester.  If the original container is not available, pack
the tester in a suitably padded box or carton.

Privacy Statement - Press Release - Copyright Information. - Contact Us