Figure 2-1. Hydraulic Module Removal/Installation
Up
TM-55-1730-229-34 Power Unit Aviation Multi-Output GTED Electrical Hydraulic Pneumatic (AGPU) Wheel Mounted Self-Propelled Towable Manual
Next
REMOVAL AND INSTALLATION OF EXHAUST EJECTOR.

TM
55-1730-229-34
AG
320A0-MME-000
TO
35C2-3-473-2
TM
1730-34/1
(3) Remove AGPU roof.
Refer to
(9) Remove nuts (12), capscrews
(14), and washers (13) that secure front
TM 55-1730-229-12, paragraph 4-16.
of hydraulic module to AGPU frame.
(4) At hydraulic module control
panel:
(a) Set RESERVOIR selector to
The hydraulic module weighs ap-
AGPU ,  refer to paragraph 2-7,  TM 55-
proximately 220 pounds empty and
1730-229-12.
280 pounds when the reservoir is
full.  Use lifting equipment to
(b) Open GAUGE SHUTOFF valve 1/4
turn,  refer to paragraph 2-7,  TM 55-
prevent personnel injury.
1730-229-72.
(10) Slide hydraulic module forward
onto lifting device.  Lower module and
(c) Observe  OUTPUT PRESSURE
gauge for zero pressure. If any pres-
place on blocks or transport to another
work area.
sure is indicated, open HIGH PRESSURE
BYPASS to relieve pressure in system.
Installation. (See figure 2-1.)
b.
NOTE
When disconnecting hydraulic hoses
some hydraulic fluid spillage will
The hydraulic module weighs ap-
occur.  Be prepared to catch fluid
proximately 220 pounds empty and
when hoses are disconnected.
280 pounds when the reservoir is
full.  Use lifting equipment to
(5) Disconnect hydraulic hose con-
nectors, (3) and (4) from hydraulic mod-
prevent personnel injury.
ule (5).  Remove and discard seals (19).
Cover ends of hydraulic hoses and hy-
(1) Position lifting device under
draulic module connectors with plastic
hydraulic module and lift module up to
caps or material to prevent contaminant
level of AGPU floor.
entry.
(6) Disconnect hydraulic hose (6)
(2) Slide hydraulic module into
AGPU hydraulic module compartment.
and quick-disconnect (7) from hydraulic
module (5).  Cover end of hydraulic hose
and  hydraulic  module  connector  with
(3) Install capscrews (14), wash-
plastic caps or material to prevent con-
ers (13), and nuts (12) to secure front
of hydraulic module to AGPU frame.
taminant entry.
(4) Install four capscrews (8) and
(7) Disconnect electrical connec-
washers (9, 10) through two brackets
tor (P14) (21) from back of hydraulic
(11) that secure back of hydraulic mod-
module.
ule to AGPU frame.
(8) Remove four capscrews (8) and
washers (9, 10) from two brackets (11)
(5) Remove protective covers from
that secure back of hydraulic module to
hydraulic hoses and connectors on hy-
draulic module.
AGPU frame.
2-34