Allow primer to dry 2 or 3 minutes be-
(c) Bend locking keys inward and
fore installing the stud.
Remove stud using an
break them off.
easy-out tool.
2
Through holes in compo-
nents shall be coated to cover all in-
ternal surfaces through to the adjacent
painted surfaces. The end of the stud
Use solvent in a well-ventilated
need not be covered.
area. Avoid excessive skin con-
tact or prolonged inhalation of
(f) While the primer is still
vapor. Do not use near open flame
soft, stud shall be turned into threaded
or in area where high temperatures
hole until step is 0.010 to 0.030 inch
below machined surface. Using a punch,
prevail.
drive lock keys into keyways of stud un-
til flush with step of stud.
(d) Clean components
using
cleaner (Dowclene) to remove all traces
NOTE
of grease or oil and the cleaner shall
be allowed to evaporate before the next
Surfaces adjacent to the locking de-
step.
vice of the stud shall be touched up
by wiping on a thin even wet coat of
primer to seal scratches and insulate
dissimilar metal surface. A thin
(e) Apply a thin even coat of
even coat of primer shall be applied
threaded hole to receive the stud. Ap-
to the area around the studs to seal
plication of primer shall be uniform and
all surfaces from the joint in all
neat in appearance without bare spots or
directions.
runs.
(g) Allow primer to cure 4 to 6
(f) Blind holes shall be
hours at room temperature or for 1 hour
coated to cover the adjacent walls with
at 82 to 135C (180 to 275F)
primer. The bottom need not be covered.
prior to assembly usage.
Section IV.
REMOVAL AND INSTALLATION OF MAJOR COMPONENTS
2-7. GENERAL.
With the exception of
c. Removal/installation of engine/
propulsion system components and hydrau-
lic pump, removal of major components
must be accomplished in the following
sequence.
Installation sequence is in
2-8. REMOVAL AND INSTALLATION OF HY-
DRAULIC MODULE.
the reverse order.
a. Removal/installation of hydraulic
(1) Disconnect battery.
(2) Remove front panel (2) by re-
moving 10 screws (1).
2-32