Table 2-2.
Direct/General Support Troubleshooting (continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
FLUID TEMPERATURE HIGH (continued)
28.
Fins of cooler are fragile and easily bent. Use care when
cleaning to prevent damage.
c. Clean contamination from cooler.
Reassemble module according to the procedure of paragraph
d.
Step 2.
Eliminate problem (which is caused by either internal contamination
in cooler or having coolers internal check valve stuck in open
position) by replacing cooler (7, figure 8-15):
a. Disassemble module to gain access to cooler. Use procedures
of paragraph 8-16 steps a. through m.
Remove cooler and copper seals (paragraph 8-16, step n.).
b.
Install new cooler with new copper seals (paragraph 8-18,
c.
step x.).
Reassemble module using the procedure of paragraph 8-18
d.
starting with step y.
UNABLE TO DRAIN OR FILL AGPU FROM DUAL MANIFOLD.
29.
Check dual manifold FILL/DRAIN valve:
Remove (paragraph 8-14) and clean FILL/DRAIN valve and clean
a.
dual manifold hole where valve fits.
b.
Inspect valve cartridge for signs of blockage (i.e., lodged
bits of packing).
Replace valve packing.
c.
d.
Re-install FILL/DRAIN valve (paragraph 8-14) and verify
operation.