Table 1-1. Tabulated Data - continued
Up
TM-55-1730-229-12 Power Unit Aviation Multi-Output GTED Electrical Hydraulic Pneumatic (AGPU) Wheel Mounted Self-Propelled Towable Manual
Next
Table 1-1. Tabulated Data - continued

TM 55-1730-229-12
TO 35C2-3-473-1
Table 1-1.
Tabulated Data (continued)
2.
Engine
(continued)
Exhaust Gas Temperature Limits:
(continued)
Allowable above 60%
1300ºF (704ºC) maximum
rotor speed
Allowable at 100%
1255ºF (679ºC) maximum
Speed
3.
Battery.
Type:
Lead-acid MIL-B-83769D, or optional NiCad MS24498
Voltage:
24 vdc
Amp-Hours: 53
4.
Battery Charger.
Manufacturer:
Leland Electrosystems, Smith Industries,
Aerospace (Cage 07639)
Model:
DSH831-1A
Voltage:
Output selectable at 28.5, 30.5, or 32 vdc
Output:
50 amperes nominal ­ battery
20 amperes nominal ­ control circuits
5.
Generator and Generator Control Unit (GCU).
Manufacturer:
Leland Electrosystems, Smith Industries,
Aerospace (Cage 07639)
P/N 83-360A:
AGH815-1 (Generator)
CSV 3370-2 (Generator Control Unit)
Rated-continuous duty, single mode:
AC 30 KW, 3 phase, 400 Hertz, 115/200V, 0.8 power factor
DC700 amperes, 28vdc
P/N 83-360D:
AGH815-3 (Generator)
CSV 3370-3 (Generator Control Unit)
Rated-continuous duty, single mode:
AC 38.4 KW, 3 phase, 400 Hertz, 115/200V, 0.8 power factor
1-20