![]() ![]() TM 55-1730-229-12
HYDRAULIC FLUID
Hydraulic fluid under high pressure is generated (up to 3300 psi) as a result of operation of the AGPU. Do not
expose any part of the body to a high pressure leak in the hydraulic system. Never attempt to connect or disconnect
hydraulic fittings under high pressure. Ensure that hoses are in good condition, not kinked, and securely connected
to aircraft before applying hydraulic power. Wear gloves and eye protection (goggles or face shield) when operating
hydraulic systems.
EXTREMELY HOT AIR
Extremely hot air under pressure is generated by the AGPU pneumatic system. Allow pneumatic hose and fitting to
cool before touching. Wear gloves and eye protection (goggles or face shield) when operating pneumatic system.
Never set PNEUMATIC POWER switch to ON unless pneumatic hose fitting is securely attached to aircraft. The
hose will attempt to straighten out with power applied, and whip around violently if not securely attached to aircraft.
NOISE
Operating level of this generator can cause hearing damage. Ear protectors, as recommended by the medical or
safety officer, must be worn when working near the AGPU. Require all personnel within 9.1 meters of the AGPU to
wear army approved hearing protectors, earplugs or noise muffs, when the turbine engine is operating.
DEGREASING SOLVENT, MIL-PRF-680
Degreasing Solvent, MIL-PRF-680 is combustible and toxic to eyes, skin, and respiratory tract. Wear protective
gloves and goggles/face shield. Avoid repeated or prolonged contact. Use only in well-ventilated areas (or use
approved respirator as determined by local safety/industrial hygiene personnel). Keep away from open flames or
other sources of ignition.
ACCESS DOORS
Open access doors may be blown shut if AGPU is operated in close proximity to hovering or taxiing aircraft.
Change 10
|
|