POWER DISTRIBUTION UNIT - continued
Up
TM-3-4240-302-30-P-5 Power Distribution Unit (NSN 4240-01-068-8645) Manual
Next
POWER DISTRIBUTION UNIT - continued

TM 3-4240-302-30&P-5
LOCATION
ITEM
ACTION
REMOVAL
Loop clamp
1.
Remove power distribution unit panel (p. 2-27).
2.
Secure screw (1) with wrench.
3.
Using a second wrench, remove nut (3).
4.
Remove screw (1).
5.
Spread ends of loop clamp (4) and slip over
tube (5).
6.
Discard loop clamp (4).
INSTALLATION
Loop clamp
1.
Spread ends of replacement loop clamp (4).
2.
Slip loop clamp (4) over tube (5).
3.
Insert screw (1) through bracket (2) and loop
clamps (4).
4.
Secure screw (1) with wrench.
5.
Using a second wrench, tighten nut (3). Take
care not to overt ighten.
6.
Replace power distribution unit panel (p. 2-27).