![]() ![]() TM 11-6130-266-15
Figure 5-3. Post regular control assembly 12, parts location.
(3) The normal resistance of replacement parts
Measured between
Dc resistance
may differ slightly from the values given in the
Part
terminals
(ohms)
A2L3
1-2
Less than 1.
A2L4
1-2
Less than 1.
A2L5
1-2
Less than 1.
b.
The resistances of the coils are listed below:
A2L6
1-2
Less than 1.
A4A1L1
10-11
400
Measured between
DC resistance
12-13
150
Part
terminals
(ohms)
12-13
150
L1
1-2
Less than 1.
14-15
2
3-9
9
16-17
10
T1
9-11
Less than 10.
18-19
10
12-14
Less than 1.
A4A1T1
1-2
56
A1K1
1-16
650
3-5
5.8
A1K2
1-16
650
6-7
1.26
A2L1
1-2
Less than 1.
8-9
1.26
A2L2
1-2
Less than 1.
A6K1
3-6
428(PP-6224/U)
X1-X2
*260(PP-6224A/U)
* Measure with DS2 NORM indicator lamp pulled out
5-6 Change 3
|
|