![]() ![]() TM 11-6130-243-35
b. Dc Resistance of Transformers and
power supply and when the circuit breaker
Coils. The dc resistance data ((3) below) is
switch is at POWER ON. Place the circuit
provided as an aid to troubleshooting. When
breaker switch to off (down) and disconnect
using the data, observe the
the input power cord.
following:
Caution: Do not measure resistance of the
(1) Before making resistance measure-
windings when input power is applied to the
ments of the windings, determine
2-5
|
|