Chapter 1. INTRODUCTION
Up
TM-11-6130-243-12-1 Power Supply PP-4606A/G Manual
Next
Chapter 2. INSTALLATION AND OPERATING INSTRUCTIONS

TM 11-6130-243-12-1
cator lamp and the jumpers are placed into a
1-6. Description
pocket on the right-hand side of the power
supply cabinet, which is accessible when the
front panel is removed. The four-wire ac in-
Power supply PP-4606A/G is a two-wheel
mobile unit in a metal cabinet, 43 1/2 inches
put cable consisting of a red, a white, a black,
and a green wire (the green wire is for ground
high, 24 1/2 inches wide, and 26 1/2 inches
connection) is 100 feet long. The two-wire dc
deep. All operating controls are mounted on
output cable terminates in a molded and keyed
the front panel. Louvers on the panels of the
cabinet and a fan are provided for air circu-
female connector and is 16 feet long. A dust
and moisture seal boot is provided for protec-
lation. A terminal block with power transformer
tion of the INPUT POWER circuit breaker
terminal jumpers (fig, 2-2 and 2-3) is in-
switch. The dust and moisture seal boot is of
stalled on each of the three power transformers
flexible plastic material that does not interfere
behind the front panel of the PP-4606A/G
with positioning the INPUT POWER circuit
so that either 220- or 440-volt ac input power
breaker switch. Exercise care when energizing
may be utilized. The power supply includes one
the circuit breaker so that the boot will not
spare indicator lamp and two spare power
be damaged.
transformer terminal jumpers. The spare indi-