Click here to make tpub.com your Home Page

Page Title: TESTING AND TROUBLESHOOTING CIRCUIT CARD ASSEMBLY PC101(A1).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Back
Section II. TROUBLESHOOTING
Up
TM-11-5820-765-34 Power Supplies PP-4763/GRC (NSN 5820-00-937-7690) and PP-4763A/GRC (NSN 5820-00-113-9768) Manual
Next
Voltage and Oscilloscope Measurements, A1 (PP-4763A)

TM 11-5820-765-34
Checking PC101
Measure: Resistance of assembly components.
Connection: Location of connector terminals PC101:
Reverse resistance
Forward resistance
PC101J101 Between terminals
.
10K
12-30
Higher (greater than 20K)
12-26
10K
Higher (greater than 20K)
1K-4K
4-6
1K-4K
11K
12-34
Infinity
45K
45K
26-30
Zero
6-12
Zero
High (greater than 10K)
High (greater than 10K)
6-36
High (greater than 10K)
High (greater than 10K)
6-38
High (greater than 10K)
10-22
High (greater than 10K)
200K
14K
10-12
Checking A1 (PP-4763-A)
Measure: Resistance of assembly components.
Test points: A1TP1 through A1TP6.
Connections: Location of test points:
Make same resistance measurements as above (refer to fig. 2, para 3-6).
Make direct resistance measurements of A1 components, using these test points:
Reverse
Resistance
A1J101
Terminals
Forward
Resistance
A1 Test Points Between
400K
A1TP3
Infinity
34
12
A1TP2
12
A1TP5
Infinity
A1TP1 to A1TP2
50K
0
l00K
12
A1TP6
A1TP4
2.1 K
6
2.5K
3-4