EQUIPMENT DATA. - Continued
Up
TM-5-3610-295-13P-1 Editorial and Photochemical Shelter Manual
Next
Figure 1-4.  Editorial Shelter Wiring Diagram

TM 5-3610-295-13&P-1 1-12. EQUIPMENT DATA. - Continued o. Air Conditioner. Manufacturer A.R.E. Manufacturing Co., Inc. Model A9KH-115P Capacity Cooling 9,000 BTUHR (9503 kJ/hr) Heating 7,000 BTUHR (7391 kJ/hr) Volume 5.1 cu ft (0.14 m3) Dimensions Length 26 in. (66.04 cm) Width 23 3/4 in. (60.33 cm) Height 16 in. (41 cm) Weight 200 lb (90.7 kg) Power Requirements 115 V, 50/60 Hz, single phase p. Blackout Warning Buzzer. Manufacturer EDWARDS COMPANY INC. Model 340-A Power Requirements 120 V, 60 Hz, 0.04 amp 1-13. ELECTRICAL DATA. The total electric demand load for the shelter components is 7 KW. Refer to Figure 1-4 for the editorial shelter wiring diagram. 1-14