Table 2-1.  Operator Preventive Maintenance Checks and Services (PMCS) (Cont.)
Up
TM-5-3610-294-13P Modular Printing System (MPS) Module C Press Section of the Army Special Warfare Modular Printing System Manual
Next
Figure 2-1.  Power Distribution Panel Controls and Indicators

TM 5-3610-294-13&P CHAPTER 2.  OPERATING INSTRUCTIONS SECTION I.  DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS 2-1. POWER  DISTRIBUTION  PANEL.    Refer  to  Figure  2-1  for  location  of  controls  and  indicators.    Numbers  in parenthesis after control or indicator listed below appear as callouts in figure. a. Circuit  Breaker  (1)  -  Provides  overload  protection  for  interior  utility  outlets  mounted  on  left  rear  wall  and  air conditioner room light. b. Circuit Breaker (2) - Provides overload protection for interior utility outlets mounted on hinged right front and rear walls and emergency light outlet. c. Circuit Breaker (3) - Provides overload protection for interior utility outlets mounted on left front wall. d. Circuit Breaker (4) - Provides overload protection for 36,000 BTUH  air conditioner supply receptacle mounted on power entry panel. e. Main Circuit Breaker (5) - In ON position, delivers electrical power to individual circuit breakers.  In OFF position, turns off all electrical power in shelter, except for the phase monitor assembly. f. Circuit Breaker (6) - Provides overload protection for ground fault interrupter utility outlet mounted on power entry panel. g. Circuit Breaker (7) - Provides overload protection for ceiling lights and blackout warning system. h. Circuit Breaker (8) - Provides overload protection for paper cutter. i. Circuit Breaker (9) - Provides overload protection for 24,000 BTUH  air conditioner. j. Blackout Override Switch (10) - In the ON position, overrides door activated blackout switch mounted on the front wall adjacent to the personnel door.  During blackout conditions switch must be in the OFF position. k. Incandescent Light Switch (11) - In the ON position, turns on front left wall light.  In OFF position, turns off left front wall light. 2-1