Figure 2-18.  Setting Up Sink Assembly
Up
TM-5-3610-293-13P Modular Printing System (MPS) Module B Press Section of the Army Special Warfare Modular Printing System Manual
Next
PREPARATION FOR MOVEMENT.  Continued

TM 5-3610-293-13&P 2-15.  PREPARATION FOR MOVEMENT. WARNING Never connect or disconnect any power cables when electrical power is energized to the cables.  Failure to do so will result in damage to equipment and/or serious injury or DEATH to personnel. a. Place all ON/OFF power switches on all operating equipment in the shelter in the OFF position. b. Place all circuit breakers and switches on the Power Distribution Panel in the shelter in the OFF position. c. Notify Module C operator that you are ready for the main circuit breaker CB1 on the Power Distribution Box to be put in the OFF position.  Wait until Module C operator has put the Power Distribution Box main circuit breaker CB1 in the OFF position before performing step d. d. Disconnect power cable between the Power Distribution Box and the Press Section shelter.  Roll power cable and place  in  storage  compartment  behind  cargo  doors  under  AC  units.    Disconnect  grounding  rod  wire,  remove  grounding rod, and stow in storage rack. e. Drain lubricating oil from side covers of printing press (Refer to TM 5-4210-304-10).  Spray unpainted surfaces with lubricant (Appendix E, item 22).  Place cover on printing press. f. Return all tools, and materials and other small items to their proper storage locations. g. Secure all cabinet and storage compartment doors. h. Unplug  electrical  cords  of  the  ceiling  fluorescent  light  assemblies  in  the  expanded  sections  of  the  shelter. Remove light assemblies by depressing the safety release button, sliding the light assemblies in their overhead storage locations  in  the  center  section  of  the  shelter  and  secure  their  electrical  cords  in  their  storage  clips.    Secure  light assemblies with safety release brackets. NOTE Each equipment item to be stowed in the shelter center section is marked with a colored  dot.    There  is  a  corresponding  colored  dot  on  the  shelter  ceiling  and floors.  Items are to be stored in the order listed below by matching the colored dot on the equipment with its matching colored dot in the floor and ceiling of the shelter center section. 2-40