Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: CHAPTER 2. OPERATING INSTRUCTIONS
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Back
1-13. PRINCIPLES OF OPERATION. -Continued
Up
TM-5-3610-293-13P Modular Printing System (MPS) Module B Press Section of the Army Special Warfare Modular Printing System Manual
Next
Figure 2-1.  Power Distribution Panel Controls and Indicators

TM 5-3610-293-13&P CHAPTER 2.  OPERATING INSTRUCTIONS SECTION I.  DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS 2-1.  POWER    DISTRIBUTION  PANEL  Refer   to   Figure   2-1   for   location   of   controls   and   indicators.      Numbers   in parenthesis after control or indicator listed below appear as callouts in figure. a. Circuit Breaker (1) - Provides overload protection for interior utility outlets mounted on left rear wall and air conditioner room light. b. Circuit Breaker (2) - Provides overload protection for interior utility outlets mounted on hinged right front and rear walls and emergency light outlet. c. Circuit Breaker (3) - Provides overload protection for interior utility outlets mounted on left front wall. d. Circuit  Breaker  (4)  -  Provides  overload  protection  for  36,000  BTUH  air  conditioner  supply  receptacle mounted on power entry panel. e. Main Circuit Breaker (5) - In ON position, delivers electrical power to individual circuit breakers.  In OFF position, turns off all electrical power in shelter, except for the phase monitor assembly. f. Circuit  Breaker  (6)  -  Provides  overload  protection  for  ground  fault  interrupter  utility  outlet  mounted  on power entry panel. g. Circuit Breaker (7) - Provides overload protection for ceiling lights and blackout warning system. h. Circuit Breaker (8) - Provides overload protection for printing press. i. Circuit Breaker (9) - Provides overload protection for 24,000 BTUH air conditioner. j. Blackout Override Switch (10) - In the ON  position, overrides door activated blackout switch mounted on the front wall adjacent to the personnel door.  During blackout conditions switch must be in the OFF position. k. Incandescent Light Switch (11) - In the ON position, turns on left front wall light. In OFF position, turns off left front wall light. 2-1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing