![]() ![]() TM 5-3610-220-14
Page 2-15. Figure 2-14 is superseded as follows.
Figure 2-14. Placing film on vacuum back.
and lens caps (3) and (5). A special lens box (2) is provided
Pages 3-5. Paragraph 3-10 a and b (1) is changed to read:
to store the lens when it is not mounted on the camera.
3-10. Lens, 19 Inch
b. Removal. With knobs (3, fig. 2-13), turn the lens
a. General. The 19 inch lens (1, fig. 2-10) is a Nikon
mounting plate (1, fig. 2-13), 15° in a counterclockwise
Apo-Nikkor lens equipped with an attached mounting plate (4)
direction to release it from the inner lensboard frame (2, fig. 2-
and lens caps (3) and (5). A special lens box (21) is provided
13).
to store the lens when it is not mounted on the camera.
Page 4-5. Figure 4-1 callout "4" is changed to read:
"4 Socket hd. mach. screw # 6-32 x 38 lg." Page 4-7.
b. Removal.
Paragraph 4-16 is superseded as follows:
(1) Grasp the knobs (3, fig. 2-11) on the lens
4-16. Vacuum Back Valve Control Knob
mounting plate (1), and rotate 150 counterclockwise to
unlock the lens (4) from the inner lensboard frame (2).
a. Removal. Unscrew one #10-32 flat head screw in the
Page 3-6. Paragraph 3-11 a and b are changed to read:
center of the knob. Lift off the knob.
b. Installation. Replace the knob on the dowel pins and
3-11. Lens, 24 Inch
fasten with the # 10-32 flat head machine screw.
a. General. The 24 inch lens (1, fig. 2-12) is a Nikon
Apo-Nikkor lens equipped with an attached mounting plate (4)
18
|
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |