Table 5-1. Troubleshooting - continued
Up
TM-5-3610-220-14 Camera Copying Mobille Process 208-Volt 3 Phase 60 Hertz Consolidated International Model 1969 NSN 3610-00-400-7588 Manual
Next
Table 5-1. Troubleshooting - continued

TM 5-3610-220-14
C4
Table 5-1. Troubleshooting - Continued
Malfunction
Probable Cause
Corrective Action
4. Pulsed Xenon Light Unit IL1500L).
NOTE
Before assuming that a light unit or a power supply channel is out verify the
condition by making sure that the suspect light does not work on any outlet If an
outlet is suspect, check that no light unit works on that outlet If an outlet is bad,
the power supply must be referred to high echelon for repair, since it does not
contain any user serviceable parts.
WARNING
Before beginning a tube replacement, make sure that the light unit is not
connected to the power supply.
a. No light, fan runs normally.
a. Tube failure.
a. Replace tube.
b. High voltage breakdown.
b. Refer to service technician.
c. Trigger circuit failure.
c. Refer to service technician.
d. Thermal safety circuit open.
d. Refer to service technician.
e. Cover glass safety circuit open.
e. Unit MUST have cover glass, with safety
pin place, to operate.  Check that cover
glass has safety pin epoxied to one edge.
If pin is broken off, refer to factory.  Pin
must align with hole in flange for proper
operation of safety circuit. When installing
cover glass a "click" should be heard when
safety switch is closed. Fasten cover glass
in place with glass clip and screws.
b. Light stutters at start of exposure.
a, b, or c above.
a, b, or c above.
c. Light starts okay after 1 to 5 second
a, b, or c above.
a, b, or c above.
delay.
WARNING
Disconnect light unit form power supply before removing
cover glass, or before servicing light unit in any way.
9