Fan Motor.
Up
TM-5-3610-220-14 Camera Copying Mobille Process 208-Volt 3 Phase 60 Hertz Consolidated International Model 1969 NSN 3610-00-400-7588 Manual
Next
Section I. 1. VACUUM BLOWER ASSEMBLY (MODEL 1969M)

TM 5-3610-220-14
C4
(a) Place Autotransformer in position and
CAUTION
secure with four screws, lockwashers and nuts.
Do not adjust Trimpot on circuit
(b) Connect wires, noting wire color and
board. Circuit board has been preset
order as tagged.
at the factory.
i. 7 Amp Choke (A3750 Rev. 8).
(c)  Replace
the
fuse
corresponding
to
the
replaced circuit board.
(1)
Removal.
Remove the four chokes as
follows.
f. 115 volt Relay (PR7A60) (Figure 4-10.1).
(a) Tag wiring noting color and order for
reassembly and disconnect wiring.
(1)
Removal.
(b) Remove four screws, lockwashers and
(a) Remove two screws, nuts and lock
nuts that secures the choke to the Power Supply housing and
washers that secure the relay to the Power Supply Assembly
remove the choke.
housing.
(2)
Installation.
Install the four chokes as
(b) Disconnect wiring to the relay.
follows:
(c) Tag wires noting color and order for
(a) Place the choke in position and secure
reassembly.
to Power Supply housing with four mounting screws, nuts and
(d) Remove relay.
washers.
(2)
Installation.
(b) Connect wiring, noting wire color and
order as tagged at disassembly.
(a) Install relay in position in Power Supply
and secure with two screws, washers and nuts.
j. Capacitor (PW951-5216).
Refer to fig. 4-10.1.
Remove and install the four capacitors as follows.
(b) Connect wires, noting wire color and
order as tagged at disassembly.
(1)
Removal.
(a) Tag the four wire leads and disconnect.
g. 230 Volt Relay (8502-SBO2-24017 (Figure 4-10.1).
(b) Remove two screws, lockwashers and
nuts. Remove the main capacitor support bracket.
(1)
Removal
(c) Remove one screw, lockwasher and
(a) Remove two screws, nuts and washers
nut. Remove clip.
that secure the relay to the Power Supply housing.
(d) Remove two screws, lockwashers and
(b) Tag wires noting color and order for
nuts and remove mounting clamp.
reassembly and disconnect wires.
(e) Remove the capacitor from the Power
(c) Remove the relay from the Power
Supply.
Supply Assembly.
(2)
Installation.
(2)
Installation.
(a) Place capacitor in position with main
(a) Install relay in position in Power Supply
support bracket in place. Secure support bracket to Power
and secure with two screws, washers, and nuts.
Supply Housing with two screws, nuts and lockwashers.
(b) Connect wires, noting wire color and
(b) Install the mounting clamp and secure
order as tagged at disassembly.
with two screws, nuts and lockwashers.
(c) Install the clip and secure with screw,
h. Autotransformer Assembly (A3942-1).
nut and lockwasher.
(d) Connect wiring noting wire color and
(1)
Removal
order as tagged.
(a) Tag wires noting color and order for
reassembly and disconnect wires.
k. Receptacles (MS3102A-18-11S-639).
(b) Remove four screws, lockwashers and
(1)
Removal
nuts and remove the Autotransformer.
(a) Remove two screws, lockwashers and
(2)
Installation.
nuts.
(b) Remove retainer.
5